Nothing Operates | Main breaker is off | Set to on |
Sub-panel breaker is off | Set to on |
Equipment GFCI is off | Set to on |
Power switch is off | Set to on |
Power cord is not plugged in | Plug in cord |
Over or high temperature protection is on | Refer to the error identification information in your owner’s manual |
No, Low Or Surging Water Flow | Air lock in the plumbing system | “Bleed” the system |
Restricted flow | Ensure that the water shut-off valves are open and that suction fittings are not blocked by debris |
Dirty filter | Clean or replace the filter |
Low water level | Increase water level to the recommended level |
No or Low Speed Pump Operation | Low level programming is incorrect | Contact your local dealer or manufacturer |
Over or high temperature protection is on | Press the button to reset |
Pump not plugged in | Plug in the pump |
No Jets Or Blower Operation | Blower or pump not plugged in | Plug in the blower or the pump |
Over or high temperature protection on | Press the button to reset |
No Therapy Jet Operation | Water shut-off valves are closed | Open shut-off valves |
Dirty filter | Clean or replace the filter |
Jets not properly adjusted | Adjust jets properly |
Thermal overload tripping | Check for restricted flow of the water |
Over or high temperature protection on | Press the button to reset |
Water Leaks | Spa is overfilled | Adjust the water level |
Too many people are in the spa | Adjust the water level |
Drain-valve left open | Close the drain valve |
Couplings or unions are loose | Tighten or contact your local dealer or manufacturer |
Plumbing or connections are leaking | Contact your local dealer or manufacturer |
Water is in the air blower plumbing | Contact your local dealer or manufacturer |
No Heat | Temperature is not set correctly | Adjust the set point |
Over or high temperature protection is on | Press the button to reset |
Current limiting is on (120V systems will not heat if high speed or Blower is on) | Contact your local dealer or manufacturer |
No power | Reset the breaker at the service panel |
Low water flow | Clean or replace the filter |
High Heat | Temperature sensor is not in the dry-well | Place sensor in the dry-well |
Temperature is set too high | Adjust the set point |
High ambient temperature | Remove the spa cover |
GFCI Trips Occasionally | Lightning or electrical storm, power surge, extremely humid conditions or radio frequency interference | Reset the GFCI NOTE: GFCI must be properly grounded and bonded |
GFCI Trips Immediately | Defective component | Contact a qualified service technician or manufacturer for assistance |
No Light Operation | Light bulb defective | Replace the bulb or contact your local dealer or manufacturer |
Reflector has fallen off | Replace the deflector or contact your local dealer or manufacturer |
Light not plugged in | Plug in the light |